General Information for APC Power Distribution Unit
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309, Metered, 0U, Three-phase, Vertical, Black, 42 AC outlet(s)
NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the
event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment. NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309
Further details for this product, NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309, can be found at the manufacturer website. Please note, these web addresse(s) are supplied by 3rd parties, Quzo UK is not responsible for the content.
NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Cable length: 1.8 m. Nominal input voltage: 200 - 240, 346 - 415 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz. Certification: UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1
Warranty information: 3 years repair or replace
Read more »
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309 APDU10450SM Specifications
Product Type
Power Distribution Unit
Brand
APC
Collection Model APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 6
Manufacturer Product Type
APC Power Distribution Unit
Product colour
Black
PDU types Metered
AC outlets quantity 42 AC outlet(s)
AC outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler
Maximum current 60 A
AC input frequency 50 - 60 Hz
Type
Three-phase
Depth 7.5 mm
Height 182.6 mm
Weight 12.7 kg
Width 5.6 mm
Mounting Vertical
Rack capacity 0U
Operating temperature (T-T) -5 - 60 C
Non-operating altitude 0 - 15240 m
Operating altitude 0 - 3048 m
Storage temperature (T-T) -25 - 65 C
Operating temperature (T-T) 23 - 140 F
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Certification UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 subpart B
CE
EN 62368-1
Total carbon footprint (kg of CO2e) 24171.76
Package width 132 mm
Package depth 262 mm
Package height 1980 mm
Package weight 15.7 kg
Number of phases 3
Cable Length 1.8 m
Nominal input voltage 200 - 240, 346 - 415 V
Colour of product Black
MPN APDU10450SM
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309 APDU10450SM Reviews