General Information for APC Power Distribution Unit
APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309, Metered, 0U, Three-phase, Rackmount, Vertical, Black
NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power
loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment. NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
Further details for this product, NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309, can be found at the manufacturer website. Please note, these web addresse(s) are supplied by 3rd parties, Quzo UK is not responsible for the content.
NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler, Power plug: IEC 60309. LED indicators: Activity, Network, Power, Cable length: 1.8 m, Security algorithms: 128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3. Monitoring: Current, Humidity, Power, Temperature,
Warranty information: 3 years repair or replace
Read more »
APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 APDU10350ME Specifications
Product Type
Power Distribution Unit
Brand
APC
Collection Model APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets,
Product colour
Black
Form Factor
Rackmount
PDU types Metered
LED indicators Activity, Network, Power
Display LCD
On/off switch Yes
Security algorithms 128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
AC outlets quantity 48 AC outlet(s)
Ethernet LAN (RJ-45) ports 2
Power plug IEC 60309
AC outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler
USB ports quantity 1
Maximum current 32 A
AC input frequency 50 - 60 Hz
Load capacity 22100 VA
Maximum total current draw per phase 32 A
Maximum power 22000 W
Password protection Yes
Type
Three-phase
Height 1780 mm
Width 56 mm
Depth 75 mm
Weight 8.4 kg
Mounting Vertical
Reset button Yes
Daisy chain Yes
Monitoring Current, Humidity, Power, Temperature, Voltage
Outlet control Lock-out, Recycle, Turn off, Turn on
Firmware upgradeable Yes
Firmware upgradeable via Network, USB
Surge protection Yes
Power protection features Overload
Rack capacity 0U
Colour-coded outlets Yes
Output Voltage 230 V
Operating temperature (T-T) -5 - 60 C
Non-operating altitude 0 - 15240 m
Operating altitude 0 - 3048 m
Storage temperature (T-T) -25 - 65 C
Operating temperature (T-T) 23 - 140 F
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Compliance certificates RoHS
Total carbon footprint (kg of CO2e) 13750.11
Regulatory Approvals CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Package width 262 mm
Package depth 132 mm
Package height 1980 mm
Package weight 11.4 kg
Number of phases 3
Cable Length 1.8 m
Nominal input voltage 400 V
Nominal output voltage 230 V
Compatible products Compatible with most NetShelter SX
enclosures and third-party racks
MPN APDU10350ME
APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 APDU10350ME Reviews